Bulông hóa chất Hilti Re500+HAS
Giá: Liên hệ

 

 HIT-RE 100 injection adhesive with HAS rod

       
       
 


 

Basic loading data (for a single anchor): HIT-RE 100 with HAS, HAS-E                                     

All data on this section applies to                                                   For detailed method, see pages 229– 234.

  • concrete: as specified in the table
  • correct setting (See setting operations page 228)
  • no edge distance, spacing and other influences
  • steel grade 5.8 for M8 – M24 sizes and steel grade 8.8 for M27 – M39
    • steel failure
 
   

 

 

Mean ultimate resistance, Ru,m [kN]: concrete = C20/25

 

Anchor size

M8

M10

M12

M16

M20

M24

M27

M30

M33

M36

M39

Tensile, NRu,m

17.7 

28.2 

41.1 

77.9 

121.7 

175.2 

264.3

346.9

407.6

484.5

555.1

Shear, VRu,m

10.7 

17.0 

24.7 

46.7 

72.9 

105.0 

221.4 

269.1 

335.3 

393.5 

473.3 

 

Characteristic resistance, Rk [kN]: concrete = C20/25

 

Anchor size

M8

M10 

M12 

M16

M20

M24

M27

M30 

M33

M36

M39

Tensile, NRk

16.4 

26.1 

38.1 

72.2 

112.7 

162.0 

199.6

262.0

307.8

365.9

419.3

Shear, VRk

9.9 

15.8 

22.9 

43.2 

67.5 

97.3 

205.0 

249.1 

310.5 

364.4 

438.3 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
   

 

210

 

 

 HIT-RE 100 injection adhesive with HAS rod

 

Following values according to the
 
   


 

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

 

Anchor size

M8

M10 

M12 

M16

M20

M24

M27

M30 

M33

M36

M39

Tensile, NRd

10.9

16.6

23.8

34.7

62.9

90.6

110.9

145.6

171.0

203.3

232.9

Shear, VRd

7.9

12.6

18.3

34.6

54.0

77.8

164.0

199.3

248.4

291.5

350.6

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

 

Anchor size

M8

M10

M12 

M16

M20

M24

M27

M30 

M33

M36

M39

Tensile, NRec

7.8

11.9

17.0

24.8

44.9

64.7

79.2

104.0

122.1

145.2

166.4

Shear, VRec

5.6

9.0

13.1

24.7

38.6

55.6

117.1

142.4

177.4

208.2

250.4

 

Basic loading data (for a single anchor): HIT-RE 500 with HAS-R, -E-R, -HCR                          

 

All data on this section applies to                                                For detailed method, see pages 229 – 234.

  • concrete: as specified in the table
  • correct setting (See setting operations page 228)
  • no edge distance, spacing and other influences
    • steel grade A4-70 for M8 – M24; for A4 grade, fuk changes for the sizes M27 to M39 from 700 N/mm2 to 500 N/mm2.
    • steel failure
 
   

 

 

Mean ultimate resistance, Ru,m [kN]: concrete = C20/25

 

Anchor size

M8

M10 

M12 

M16

M20

M24

M27

M30 

M33

M36

M39

Tensile, NRu,m

24.8 

39.6 

57.8 

109.1 

170.3 

244.4 

230.7 

280.2 

349.4 

410.1 

493.0 

Shear, VRu,m

14.8 

23.8 

34.5 

65.4 

102.1 

146.9 

138.5 

168.3 

209.7 

246.0 

295.9 

 

Characteristic resistance, Rk [kN]: concrete = C20/25

 

Anchor size

M8

M10 

M12 

M16

M20

M24

M27

M30 

M33

M36

M39

Tensile, NRk

23.0 

36.7 

53.5 

101.0 

157.6 

226.3 

213.6 

259.4 

323.5 

379.7 

456.5 

Shear, VRk

13.7 

22.0 

32.0 

60.5 

94.5 

136.0 

128.2 

155.8 

194.2 

227.8 

274.0 

 

Following values according to the
 
   


 

Design resistance, Rd [kN]: concrete, fck,cube = 25 N/mm2

 

Anchor size

M8

M10 

M12 

M16

M20

M24

M27

M30 

M33

M36

M39

Tensile, NRd

12.3

16.6

23.8

34.7

62.9

90.6

89.0

108.1

134.8

158.2

190.2

Shear, VRd

8.8

14.1

20.5

38.8

60.6

87.2

64.1

77.9

97.1

113.9

137.0

Recommended load, Lrec [kN]: concrete, fck,cube = 25 N/mm2

 

Anchor size

M8

M10 

M12 

M16

M20

M24

M27

M30

M33 

M36

M39

Tensile, NRec

8.8

11.9

17.0

24.8

44.9

64.7

63.6

77.2

96.3

113.0

135.9

Shear, VRec

6.3

10.1

14.6

27.7

43.3

62.3

45.8

55.6

69.4

81.3

97.9

 

 

 

 

 
   

 

211

 

 

 HIT-RE 100 injection adhesive with HAS rod       

 

Setting details                                                                                                                                            

 

hnom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anchor size

M8

M10

M12

M16 

M20

M24

M27

M30

M33

M36

M39

Anchor rod1)

 

HAS /-E/-R/-E-R/-HCR

M8x80/ 14

M10x90/ 21

M12x110/ 28

M16x125/ 38

M20x170/ 48

M24x210/ 54

M27x240/ 60

M30x270/ 70

M33x300/ 80

M36x330/ 90

M39x360/ 100

d0

Drill bit diameter

[mm]

10

12

14

18

24

28

30

35

37

40

42

h1

Hole depth

[mm]

85

95

115

130

175

215

250

280

310

340

370

hnom

Nom. anch. depth

[mm]

80

90

110

125

170

210

240

270

300

330

360

h (min)

Min. thickness of base material

[mm]

110

120

140

170

220

270

300

340

380

410

450

tfix (max)

Max. fixture thickness

[mm]

14

21

28

38

48

54

60

70

80

90

100

df

Clearance rec. hole                   max.

[mm]

9

12

14

18

22

26

30

33

36

39

42

11

13

15

19

25

29

31

36

38

41

43

Tinst

Tightening torque [Nm]

15

30

50

100

160

240

270

300

1200

1500

1800

Filling Volume2)

 

ml

4

6

10

15

43

65

71

124

140

160

160

Trigger pulls    MD/BD 2000

1

1

2

4

9

13

15

25

28

32

32

 

Rec. drilling system

TE-

1..18M

5..18M

15..35

25..55

55..76

55..76

55..76

55..76

55..76

55..76

 

Diamond drill.

DD EC-1 / DD 100 / DD 130

DD 100 - DD 250

                             

1) The values for the maximum fixture thickness are only valid for the HAS anchor rods given in this table. If other HAS rods are used, these values will change. (Example: HAS M12x110/128; tfix = 128 mm)

2) One trigger pull is approx. 5 ml mortar when using the MD 2000 or BD 2000.

 

Temperature of the basematerial:

Working time in which anchor can be inserted and adjusted,

Curing time before anchor can be fully loaded,

40°C

30°C

20°C

10°C

0°C

-5°C

12 min.

20 min.

30 min.

2  hours

3  hours

4  hours

4 hours

8 hours

12 hours

24 hours

50 hours

72 hours

less than -5°C

Contact your Hilti advisory service.

The foil pack temperature must be at least +5°C.

 

Installation equipment                                                                                                                             

 

  • appropriate drill bit (diamond core bit)
  • dispenser (MD 2000, BD 2000, P3000 F, P5000 HY, HIT-P 8000 D)
    • blow-out pump
    • set of cleaning brushes

 

 

 
   

 

212

 

 

 HIT-RE 100 injection adhesive with HAS rod       

 

Setting operations                                                                                                                                     

 

 

 

 

 

 

 

 

 

 

       
       


 

 

 

           
           
 
 


 

 

 

 
   

 

 

 

 

 

 

p

d

lp

 
Anchor geometry and mechanical properties                                                                                   

 

Anchor size

M8

M10

M12

M16

M20

M24

M27

M30

M33

M36

M39

Anchor rod

 

HAS

M8x80/ 14

M10x90/ 21

M12x110/ 28

M16x125/ 38

M20x170/ 48

M24x210/ 54

M27x240/ 60

M30x270/ 70

M33x300/ 80

M36x330/ 90

M39x360/ 100

l   [mm]         Anchor length

110

130

160

190

240

290

340

380

420

460

510

2

As [mm ]       Stressed cross-section

32.8

52.3

76.2

144

225

324

427

519

647

759

913

 

 

2

fuk  [N/mm ]   Nominal tensile

strength

HAS 5.8

500

500

500

500

500

500

-

-

-

-

-

HAS 8.8

-

-

-

-

-

-

800

800

800

800

800

HAS-R

700

700

700

700

700

700

500

500

500

500

500

-HCR

 

f    [N/mm2]   Yield strength

yk

HAS 5.8

400

400

400

400

400

400

-

-

-

-

-

HAS 8.8

-

-

-

-

-

-

640

640

640

640

640

HAS-R

450

450

450

450

450

450

250

250

250

250

250

-HCR

W [mm3]      Moment of resistance

26.5

53.3

93.9

244

477

824

1245

1668

2322

2951

3860

 

 

HAS 5.8

12.7

25.6

45.1

117.1

228.8

395.3

-

-

-

-

-

MRd,s [Nm]

Design bending resistance1)

HAS 8.8

-

-

-

-

-

-

956.1

1280.8

1783.5

2266.5

2987.8

HAS-R

14.3

28.7

50.6

131.4

256.7

443.5

478.8

641.5

893.0

1134.9

1484.5

 

 

-HCR

Sw [mm]        Width across flats

13

17

19

24

30

36

41

46

50

55

59

dw [mm]        Washer diameter

16

20

24

30

37

44

50

56

60

66

72

Rd,s                                uk     Ms,b                                        Ms,b

 

1)    The design bending resistance of the anchor rod is calculated   from M                             = (1.2 · W · f  )/g                                , where the partial safety factor, g                                                              , for grade 5.8 and 8.8 rods is 1.25 and for 1.56 for A4-70 and HCR. The final safety check is then MSk · gF £ MRd,s

 
   

 

212

 

 

 

 

  HIT-RE 100 injection adhesive with HAS rod

 

Detailed design method - Hilti CC

(The Hilti CC method is a simplified Version of ETAG Annex C.)

Caution: In view of the high loads transferable with the HIT-RE 100, it must be verified by the user that the load acting on the concrete structure, including the loads introduced by the anchor fastening, do not cause failure,

e.g. cracking, of the concrete structure.

 

TENSION

The design tensile resistance of a single anchor is the lower of:

NRd,c : concrete cone/pull-out resistance NRd,s  : steel design tensile resistance

 

 

NRd,c: Concrete cone/pull-out resistance                                                                                           

 
   


 

 

N0Rd,c: Concrete cone/pull-out resistance

  • concrete compressive strength, fck,cube= 25 N/mm2

Anchor size

M8

M10

M12

M16

M20

M24

M27

M30

M33 

M36

M39 

No       1) [kN] concrete

Rd,c

12.4

16.6

23.8

34.7

62.9

90.6

110.9

145.6

171.0

203.3

232.9

hnom    [mm]   Nominal anchorage depth

80

90

110

125

170

210

240

270

300

Bulông hóa chất Hilti Re500+HAS
  • Đặt mua sản phẩm
    • Tên quý khách:

    • Số điện thoại:

    • Địa chỉ liên hệ:

    • Số lượng:

    • Thành tiền:

    •  

         

Chi tiết sản phẩm

Đặc điểm nổi bật của Hóa chất HILTI RE100:
Được sử dụng với thanh ren HAS để cấu thành một bộ bu loong cường độ cao;
Túi hóa chất bằng nhựa rất linh hoạt so với dạng ống thủy tinh, không bị vỡ trong quá trình vận chuyển;
Túi có hình dáng mũi tên đáp ứng được nhu cầu sử dụng trong trường hợp thi công ngược trần;
Sản phẩm có nhiều cỡ khác nhau để thi công với thanh ren từ phi 8mm đến phi 39mm. Dùng được cho cả thanh ren trong và ren ngoài;
Sản phẩm an toàn, không có hóa chất độc hại đối với môi trường và cho sức khỏe con người;
* Ứng dụng:
- Sử dụng cho các ứng dụng chịu tải cao và chịu được rung động tốt;
- Dùng cho vùng bê tông chịu nén (kết cấu thép, lắp đặt máy móc, các lan can an toàn, các kết cấu nhôm kính, các đường ray...)

Quy trình thi công lắp đặt:

Thời gian đông kết Hilti-HVU:

 Các loại Bulong HAS
- HAS M8x 80
- HAS M10x 90
- HAS M12x 110
- HAS M16x 125
- HAS M20x 170
- HAS M24x 210
- HAS M27x 240
- HAS M30x 270
- HAS M33x 300
- HAS M36x 330
- HAS M39x 360
Thông số lực kéo, lực cắt Bulong:

Sản phẩm khác

trở lên